
15
Essex Electronics, Inc. | 805.684.7601 | 800.KEY-LESS | fax 805.684.0232 | keyless.com
3. Placing a jumper across the 1st and 2nd pins of the “3,4,5
UNLOCK” option allows User Code 3, User Code 4 and User Code
5 to activate (unlock) Relay #2
4. In this example, User Code 1 and User Code 2 have also been
given Latching Authorization for Relay #1.
Note: In order for 2 Door conguration to operate correctly, be sure to
remove any jumpers across the CCTV option and the Doorbell option.
Tamper Alarm Lockout
A person attempting to gain entry by guessing the code and pushing
25 wrong digits will cause the KE-265 to go into tamper alarm mode.
The Keypad will beep constantly for 30 seconds during which
time the door will remain locked and no keypad functions can be
performed.
Kommentare zu diesen Handbüchern